12. Why does the new machine fail to respond after powering on?
【2022-03-21 】 Our machine is equipped with a phase sequence detection device. Please check whether the phase sequence is correct and the neutral wire is connected in place....
【2022-03-21 】 Our machine is equipped with a phase sequence detection device. Please check whether the phase sequence is correct and the neutral wire is connected in place....
【2022-03-21 】 1. Check whether the remote blocking detection switch is normal2. Check whether the photoelectricity of the embryonic path is normal...
【2022-03-21 】 The stretch rod is in direct contact with the product, and food grade grease must be added for lubrication. Otherwise, it will cause product contamination. Generally, once a week, one layer of oil film is sufficient....
【2022-03-21 】 That is to facilitate the lubrication of the guide rail. Please lubricate the slider according to the lubrication period table....
【2022-03-21 】 First take out the preform and bottle, then loosen the four screws that fix the connecting seat to make it in a loose state, then push the cam by hand to reset, and then lock the screws after resetting....
【2022-03-21 】 Loosen the screw on the dial, turn the dial so that the position of the dial coincides with the position of the embryo holder, and then tighten the screw. Put 2~3 preforms in manually, and stop when the preforms enter the gripper. Then gently rotate the preform by hand, and the preform will rotate s...